Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Radiol ; 76(7): 548.e25-548.e29, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33691949

RESUMO

AIM: To review the removal of Y-shaped airway self-expanding covered metallic stents using the interventional technique under fluoroscopy. MATERIALS AND METHODS: The clinical data of 33 patients who underwent removal of Y-shaped airway self-expanding covered metallic stents from March 2011 to August 2019 were analysed retrospectively. RESULTS: A total of 35 Y-shaped stents were removed. The average indwelling duration of the tracheal stents was 101.7 ± 105.4 days. Four cases were removed via the conventional method (grasping the upper tip of the stent to collapse and adduct the proximal end of the stent), whereas 31 cases were removed using the reversal method (grasping the distal end of the stent to invert and strip out the stent). The duration of stent removal was 24.3 ± 12.4 minutes (median time, 20 minutes). CONCLUSION: The interventional radiology technique is a feasible, safe, and effective method for removing Y-shaped airway self-expanding covered metallic stents, and can be considered for use in the clinical setting.


Assuntos
Remoção de Dispositivo/métodos , Stents , Adulto , Idoso , Broncoscopia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Traqueia
2.
Clin Radiol ; 75(12): 962.e17-962.e22, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32863026

RESUMO

AIM: To investigate the feasibility and safety of a fluoroscopy-assisted interventional technique for removal of bullet-shaped self-expanding covered metallic stents from bronchopleural fistulas (BPFs). MATERIALS AND METHODS: Clinical data for 49 consecutive patients who underwent removal of bullet-shaped self-expanding covered metal stents from October 2010 to November 2019 were analysed retrospectively. Fifty-one stents were removed in all, including 29 large Y-shaped bullet stents, 10 small Y-shaped bullet stents, and 12 branched bullet-shaped stents. The average duration for which tracheal stents were in place was 99.4±8.5 days. RESULTS: Fifty-one stents were removed successfully, of which 49 were directly removed on the first attempt. The time required for stent removal ranged from 7-60 minutes (median time, 22 minutes). In eight cases, the stent was removed by the conventional method (i.e., grasping the upper tip of the stent to collapse and adduct the proximal end), and in 43 by the eversion method (i.e., grasping the distal end of the stent to invert and peel out). CONCLUSIONS: Interventional radiology is a simple, safe, and effective method to extract self-expanding covered metallic bullet-shaped stents, with no need for general anaesthesia and tracheal intubation. It has a short operation time, is well tolerated by patients, and is worthy of clinical application.


Assuntos
Fístula Brônquica/cirurgia , Remoção de Dispositivo , Doenças Pleurais/cirurgia , Radiografia Intervencionista/métodos , Stents Metálicos Autoexpansíveis , Adulto , Idoso , Broncoscopia , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...